ROYAL SCIENTIFIC INDUSTRY

Ambala Cantt, India gst GST No.06AWYPA9374K1ZQ

autoclave

(2 products available)
Horizontal Autoclave
  • Horizontal Autoclave

Horizontal Autoclave

150000 INR/Piece

Minimum Order Quantity : 1 Pieces

Working Temperature 121A C / 134A C

Working Pressure 0.23 MPa

Valves Automatic & Manual Safety Valves

Type Horizontal Cylindrical

Temperature Scope Ambient to 134A C

Sterilizing Temperature 121A C / 134A C

Sterilization Time 0-999 min Adjustable

Steam Saturated Steam, External Source

Spraying Piping Stainless Steel Spray Pipes

Spraying Mode Rotary or Static

Recording Parameters Digital, Temperature & Pressure

Power Consumption 8-12 kW

Piping System 304 Stainless Steel with Automatic Valves

Outer Trolley Stainless Steel, Removable

Outer Size 2200 mm x 1000 mm x 1450 mm

Net Weight 850 kg

Insulation Glass Wool, 70 mm Thick

Inner Trolley Stainless Steel, Perforated Shelves

Heat Uniform A 1A C

Door Type Horizontal sliding door

Design Temperature 139A C

Design Pressure 0.3 MPa

Compressed Air 0.6-0.8 MPa

Chamber Thickness 8 mm

Chamber Size 1000 mm Diameter x 2000 mm Length

Payment Terms Letter of Credit (L/C), Western Union, Cheque, Cash in Advance (CID), Paypal

Main Export Market(s) South America, Eastern Europe, Western Europe, Middle East, North America, Central America, Australia, Asia, Africa

About this product

Cylindrical (Double Walled) Inner and outer chamber made of thick SS fitted with automatic pressure control switch, low water cutoff device, digital temperature controller cum indicator with inbuilt timer vacuum breaker.

Sizes in MM         In Liters Capacity         Load 

400 x 600mm       78 Liters                       6 KW

400 x 1100mm      162 Liters                    9 KW

500 x 900mm        165 Liters                    9 KW

500 x 1200mm      221 Liters                    9 KW






Advanced Sterilization Technology

Equipped with a microprocessor-based PLC and HMI touchscreen, this autoclave ensures precise, repeatable control for all sterilization cycles. The intelligent system monitors and records temperature and pressure in real time, offering complete process traceability. Its advanced rotary or static spraying mode improves steam distribution for ultra-uniform sterilization, making it suitable for diverse medical, pharmaceutical, and laboratory applications.


Superior Construction & Safety

Built entirely from high-grade 304/316 stainless steel, this autoclave demonstrates exceptional durability and corrosion resistance. Safety is prioritized through features like over-temperature and over-pressure safeguards, door interlocking, and both automatic and manual safety valves. The 70 mm glass wool insulation ensures thermal efficiency and operator protection during operation. Its robust build, horizontal sliding door, and sturdy trolley systems allow efficient loading and unloading.


Efficient Operation & User Convenience

Designed for seamless daily use, the autoclave offers automatic water supply with a reliable level sensor, as well as floor mounting for stable installation. External steam and compressed air support, rapid cycle adjustability (0-999 min), and digital recording of sterilization parameters simplify operation and maintenance. The equipment's intuitive interface allows for easy program selection, improving workflow in even the busiest settings.

FAQ's of Horizontal Autoclave:


Q: How does the microprocessor-based PLC with HMI touchscreen improve the sterilization process?

A: The microprocessor-based PLC combined with an HMI touchscreen enables precise control and easy monitoring of all autoclave functions. Users can select programs, monitor progress, and review digital records of temperature and pressure, resulting in consistent, reliable sterilization outcomes.

Q: What are the primary benefits of using 304/316 grade stainless steel in the construction?

A: Using 304/316 grade stainless steel ensures superior durability, resistance to corrosion, and ease of cleaning. This makes the autoclave suitable for demanding environments in medical, laboratory, and pharmaceutical applications where hygiene and longevity are essential.

Q: When should deionized or distilled water be used in this autoclave?

A: Deionized or distilled water is recommended at all times to prevent mineral buildup and contamination inside the chamber and piping system. This ensures optimal performance, protects the equipment from scaling, and maintains the integrity of sterilized items.

Q: Where is this horizontal autoclave best installed, considering its specifications?

A: Given its sizeable dimensions and floor-mounted design, this autoclave is ideally installed in spacious, well-ventilated sterilization rooms within hospitals, research labs, or pharmaceutical production areas. Sturdy flooring and adequate space for trolley movement are needed for optimal operation.

Q: What is the process for loading and unloading items into the autoclave?

A: Items are loaded onto the removable stainless steel outer trolley, then transferred into the chamber using the internal perforated-shelf trolley. The horizontal sliding door and ergonomic trolley design simplify safe and efficient handling before and after the sterilization cycle.

Q: How does the high-efficiency water ring vacuum pump and spraying piping system enhance usage?

A: The high-efficiency water ring vacuum pump ensures thorough air removal, while the stainless steel spraying pipes (rotary or static) guarantee uniform steam penetration. Together, they deliver optimal sterilization by achieving consistent temperature and pressure distribution throughout every cycle.

Q: What are the key safety features integrated into this autoclave and their benefits?

A: Safety measures include over-temperature and over-pressure protections, a door interlock system, and both automatic and manual safety valves. These features prevent operation under unsafe conditions, protect users from accidental exposure, and safeguard the equipment against damage.

Get a Price/QuoteRequest To Call Back
Horizontal Autoclave Triple Wall
  • Horizontal Autoclave Triple Wall

Horizontal Autoclave Triple Wall

220000 INR/Piece

Minimum Order Quantity : 1 Pieces

Working Temperature 121A C

Working Pressure 1.2 Bar

Valves SS-316 Safety & Solenoid Valves

Type Horizontal Cylindrical Triple Wall

Temperature Scope Room Temp to 134A C

Sterilizing Temperature 121A C - 134A C Adjustable

Sterilization Time 20-60 Mins Programmable

Steam Saturated Steam Supply; Boiler Integrated or External

Spraying Piping Internal SS-316 Grade Piping with Multiple Spraying Nozzles

Spraying Mode Rotary or Oscillating Spray System

Recording Parameters Digital Data Logger with Graphical Printer

Power Consumption 9 kW to 20 kW, Depending on Model

Piping System Triple Wall Construction with SS-316 Quality Piping

Outer Trolley Removable Stainless Steel Outer Trolley Provided

Outer Size 1850 x 950 x 1200 mm (L x W x H)

Net Weight Approx. 1200 kg

Insulation High-Density Mineral Wool Insulation

Inner Trolley Perforated Stainless Steel Inner Trolley Included

Heat Uniform A 1A C at 121A C Uniformity

Door Type Horizontal Sliding Door, Automatic with Safety Mechanical Lock

Design Temperature 143A C

Design Pressure 2.2 Bar

Compressed Air 6-8 Bar, Clean Dry Air Required for Operation

Chamber Thickness 6 mm (Inner Chamber Wall)

Chamber Size 600 mm x 1200 mm (D x L)

About this product

Cylindrical (Triple Walled) Inner and outer chamber made of thick SS fitted with automatic pressure control switch, low water cutoff device, digital temperature controller cum indicator with inbuilt timer vacuum breaker, automatic self locking safety door, moisture trap, purging on/off system and multiport valve.

Chamber Sizes        Chamber Sizes       Capacity       Load

    in MM                         in Inches

 400 x 600mm         16 x 24                    78 Liters       6 KW

 400 x 1100mm       16 x 36                    162 Liters     9 KW

  500 x 900mm        20 x 36                    165 Liters     9 KW

  500 x 1200mm      20 x 48                    221 Liters     9 KW 






Unmatched Build Quality and Performance

Engineered with a complete stainless steel SS 304/316 triple wall construction, this horizontal autoclave ensures superior durability and corrosion resistance. Its integrated saturated steam supply, high-efficiency immersion-type heating element, and robust vacuum pump guarantee efficient sterilization throughout every cycle, while the polished external finish adds to its professional aesthetics.


Comprehensive Safety and Control Features

The autoclave is equipped with advanced safety mechanisms, such as an automatic horizontal sliding door with mechanical locking, excess temperature cut-off, overpressure protection, and a secure door interlock. The intuitive microprocessor-based PLC control panel with LCD or touchscreen display allows for precise cycle management, temperature monitoring, and programmable sterilization times, ensuring reliable operation and peace of mind.


Versatile Operation and Easy Maintenance

With customizable cycle programs, programmable temperature (room temp to 134C), and time (2060 mins), this autoclave offers flexibility for varied sterilization needs. Floor mounted and designed for ease of access, it includes side/back service doors, removable trolleys, and SS-316 internal spray piping, making maintenance, loading, and unloading both convenient and efficient.

FAQs of Horizontal Autoclave Triple Wall:


Q: How does the triple wall construction of the autoclave enhance its performance?

A: The triple wall construction, made from SS 304/316, improves thermal insulation, energy efficiency, and ensures uniform heat distribution for consistent sterilization. This design also enhances long-term durability and safety during operation.

Q: What safety features are included in this horizontal autoclave?

A: The autoclave has multiple safety features, including an automatic sliding door with mechanical lock, door interlock system, overpressure protection, excess temperature cutoff, and both digital and analog pressure gauges for comprehensive monitoring.

Q: What is the process for starting a sterilization cycle and how are cycles customized?

A: To start a cycle, users select from preset or custom programs on the PLC control panel. Parameters like temperature (121C134C), sterilization time (2060 mins), and drying options can be adjusted. The systems data logger and graphical printer record and confirm all process parameters.

Q: Where can this autoclave be installed and what is its installation requirement?

A: This autoclave is intended for floor mounting in laboratories, hospitals, and industrial sites. Installation requires a 220V/50Hz power supply, access to clean dry compressed air (6-8 Bar), and space for the units external dimensions (1850 x 950 x 1200 mm).

Q: How is water consumption managed and what are its typical usage levels per cycle?

A: Each sterilization cycle uses approximately 3040 liters of water, circulated via internal SS-316 piping with multiple spraying nozzles to ensure thorough coverage and efficient operation.

Q: What are the benefits of the provided vacuum pump and spraying system?

A: The built-in vacuum pump removes air efficiently, ensuring complete steam penetration for effective sterilization. Coupled with rotary or oscillating spray systems, it promotes uniform exposure of instruments for optimal results.

Get a Price/QuoteRequest To Call Back

Contact Us

Message